Georgia Master Plumber License Exam (Class II Unrestricted) Exam Prep
Free practice questions

Free GAMP Practice Questions

10 exam-style questions with answers and explanations, straight from our 1,030-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.

Start the free practice test → ★★★★★4.9/5 from 2,400+ candidates · No signup

The GAMP exam has 168 questions and runs 7 hours.

These 10 free GAMP questions are organized by exam domain, so you can see how each part of the Georgia Master Plumber License Exam (Class II Unrestricted) blueprint is tested. Reveal the answer and explanation under each question.

Domain 1: Comply with General Laws 3.57% of exam

Question 1

An applicant documents 6 years of plumbing work covered by the Georgia State Plumbing Code, including 18 months while licensed as a Journeyman, plus commercial experience. The application includes three licensed-plumber references, two from Master Plumbers. What still prevents the applicant from meeting the Class II eligibility rule?

Show answer & explanation

Correct answer: C - The licensed Journeyman experience is less than two years

Domain 2: Comply with Regulations 10.71% of exam

Question 2

During inspection of a storage water heater, which relief-discharge arrangement requires correction?

Show answer & explanation

Correct answer: A - A 3/4-inch line uses internal-diameter-reducing insert fittings but remains 3/4 inch nominal

Domain 3: Work Planning/Organizing 5% of exam

Question 3

A plan uses a scale of 1/4 inch = 1 foot. Four identical pipe runs each measure 8.75 inches on the drawing. Pipe is ordered in 20-foot lengths, and the takeoff includes 8% waste. What is the minimum number of stock lengths to order?

Show answer & explanation

Correct answer: D - 8 lengths

Domain 4: Perform Pipe Cutting and Joining Activities 7.14% of exam

Question 4

An aboveground 4-inch cast-iron branch must transition to 4-inch PVC. Both sides will be independently supported so the coupling carries no pipe weight. Select the appropriate connection.

Show answer & explanation

Correct answer: B - A listed shielded transition coupling sized to both actual outside diameters

Question 5

While soldering a copper water line, the flux turns black and the solder beads on the tube instead of being drawn into the fitting cup. What is the best repair?

Show answer & explanation

Correct answer: C - Disassemble or cut out the joint, clean to bright metal, and remake it

Domain 5: Perform Plumbing Systems Installation Activities 15% of exam

Question 6

A building has a service PRV and a downstream check valve. Static pressure is 62 psi while the water heater is idle, climbs to 96 psi only during heater recovery, and falls after hot water is used. Which correction most directly addresses the cause?

Show answer & explanation

Correct answer: B - Service or size the expansion tank and set its air precharge to 62 psi

Question 7

A make-up water connection is classified by the authority as low hazard and is subject to both backsiphonage and backpressure. The equipment room cannot accommodate relief-port discharge. The specified testable assembly should be a:

Show answer & explanation

Correct answer: A - Double-check valve assembly

Question 8

For a 2-inch trap arm, the maximum distance to the vent is 8 feet, and the vent must connect before the arm drops more than one pipe diameter. Which installation complies?

Show answer & explanation

Correct answer: D - The vent connects at 7 feet after a 1.75-inch drop

Question 9

A residence will have 2.5 bathrooms and 4 bedrooms. The proposed storage water heater has a 58-gallon tank and a listed first-hour rating of 60 gallons. Under Georgia's residential first-hour-rating table, what is the correct conclusion?

Show answer & explanation

Correct answer: C - It does not comply; the minimum listed first-hour rating is 62 gallons

Question 10

During commissioning, a gas water heater's vent operates under positive pressure and carries condensate. Which classification and vent characteristic apply?

Show answer & explanation

Correct answer: B - Category IV - gas-tight, corrosion- and condensate-resistant venting

The rest of the GAMP blueprint

The GAMP exam also covers these domains. Drill them in the full free practice test:

That's 10 of 1,030

The full bank has 1,020 more GAMP questions with explanations.

Continue in the free practice test →

View plans